![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2142231.1 : Multiple Load Failures On Drive 1,2,-2,1,1 On Sl8500
In this Document
Created from <SR 3-12725985381> Applies to:IBM LTO5 Tape Drive - Version All Versions and laterInformation in this document applies to any platform. Oracle replaced drive in bay48, acsls drive 0,1,1,0 ran command on acsls : config drives 0,1,1 saw change in serial number on acsls, 2016-05-20 13:19:56 57397 drive 0, 1, 1, 0 serial number changed. on media server med01np ran command tpautoconf -report_disc saw missing drive ACS-LTO5-BAY.48-0.1.1.0 path /dev/rmt/13cbn ran command tpautoconf -replace_drive ACS-LTO5-BAY.48-0.1.1.0 -path /dev/rmt/13cbn re-ran command tpautoconf -report_disc, no issues. ran command tpautoconf -a netbackup stop bpps -x - all clear netbackup start Drive shows as available in NetBackup Start process to that drive - tape loads in drive, acsls shows tape in drive, NetBackup never shows tape in drive and job details never shows tape loaded. Symptoms Over the last few days, on several different media, load failures on drive 1,2,-2,1,1. log errors like: Changes
CauseNetbackup Issue SolutionWorked with NetBackup support, Ran tpautoconf -a and recycled netbackup and eventually the drive stayed up. Created from <SR 3-12725985381> Applies to:IBM LTO5 Tape Drive Attachments This solution has no attachment |
||||||||||||||||||||
|