Solution Type Problem Resolution Sure Solution 2142003.1 : SL3000 - INVALID Partition (0) After Firmware Upgrade to FRS_4.32 Coming From FRS_2.05
Firmware upgrade was done to SL3000 to level 4.32 coming from 2.05 Re install required Oracle license files activate and select required storage cell layout reboot libary In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. SymptomsAfter firmware upgrade to 4.32 coming from2.05 the main partition is invalid. The SL3K not partitioned into "sub-partitions" as well as 2016-05-20T15:56:43.668, 1.0.0.0.0, root, default, internal, 0, error, 3204, "System error Catalog DB Initializer:CatalogDBInitializer failed to update Catalog database, Exiting catalog setup,,, Invalid parameter value - Error : Invalid partition definition, Partitions parameter is not defined" Changes
CauseSuspect that active cells may not have been selected. SolutionPerform following steps: References<NOTE:1989859.1> - SL3000 - Newly Added Drives Not Showing Partition or HLI/SCSI Address in Non-partitioned Library<NOTE:1665331.1> - Can Upgrade SL3000 FW From Code 2.05 To 4.0 Directly ? Attachments This solution has no attachment |
||||||||||||||||||||
|