Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2142003.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2142003.1 :   SL3000 - INVALID Partition (0) After Firmware Upgrade to FRS_4.32 Coming From FRS_2.05  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


Firmware upgrade was done to SL3000 to level 4.32 coming from 2.05

Re install required Oracle license files
activate and select required storage cell layout
reboot libary

In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: INTERNAL Information
Created from <SR 3-12721731652>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

After firmware upgrade to 4.32 coming from2.05 the main partition is invalid.

The SL3K not partitioned into "sub-partitions"
However the main partition (0) is complaining
2016-05-20T15:48:52.229, 1.0.0.0.0, root, default,setPartition, 51401, error, 1202, "Invalid parameter value", parameter= Currently partition configuration is in invalid state, cannot change partition state when the whole partition configuration state is in invalid state

as well as

2016-05-20T15:56:43.668, 1.0.0.0.0, root, default, internal, 0, error, 3204, "System error Catalog DB Initializer:CatalogDBInitializer failed to update Catalog database, Exiting catalog setup,,, Invalid parameter value - Error : Invalid partition definition, Partitions parameter is not defined"

Changes

 

Cause

Suspect that active cells may not have been selected.
 

Solution

Perform following steps:

- Cell license keys files being installed.
- Are the cells activated.
- Select the active cells.

Probably the cell layout can not be validated since the partition status is invalid.
This can be fixed by performing the "partition set" command and to toggle between the current and the other host mode (HLI/SCSI) which will re validate the partition.
 

References

<NOTE:1989859.1> - SL3000 - Newly Added Drives Not Showing Partition or HLI/SCSI Address in Non-partitioned Library
<NOTE:1665331.1> - Can Upgrade SL3000 FW From Code 2.05 To 4.0 Directly ?