Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2140703.1
Update Date:2016-12-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2140703.1 :   SuperCluster: svc:/site/iodct-httpd-run-once: Default in Maintenance Mode on v1.x Systems Following JAN 2016 QFSDP  


Related Items
  • Oracle SuperCluster T5-8 Full Rack
  •  
  • SPARC SuperCluster T4-4 Full Rack
  •  
  • Oracle SuperCluster T5-8 Half Rack
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
  •  
  • _Old GCS Categories>ST>Server>Engineered Systems>SPARC SuperCluster>Patching
  •  




Applies to:

Oracle SuperCluster T5-8 Half Rack - Version All Versions and later
Oracle SuperCluster T5-8 Full Rack - Version All Versions and later
Oracle SuperCluster M6-32 Hardware - Version All Versions and later
SPARC SuperCluster T4-4 Full Rack - Version All Versions and later
Oracle Solaris on SPARC (64-bit)

Symptoms

svc:/site/iodct-httpd-run-once:default (IODCT Configuration - Run-once service)
State: maintenance since Sat Mar 05 14:50:42 2016
Reason: Requested by service method: "IODCT Service Encountered Errors.
Please see the log.."
See: http://support.oracle.com/msg/SMF-8000-AR
See: /var/svc/log/site-iodct-httpd-run-once:default.log
Impact: This service is not running.

cat /var/svc/log/site-iodct-httpd-run-once:default.log
[ Mar 5 14:19:12 Executing start method ("/lib/svc/method/iodct-httpd-run-once.sh"). ]
grep: can't open /var/tmp/ssc-data/config/computenode[12345678]_domain0.oes
df: (/production) not a block device, directory or mounted resource /production is not a mountpoint.
Exiting. Please correct this before re-starting. osc-domcreate will not be able to function until this is corrected.
[ Mar 5 14:19:13 Method "start" exited with status 100. ]
[ Mar 5 14:50:41 Executing start method ("/lib/svc/method/iodct-httpd-run-once.sh"). ]
grep: can't open /var/tmp/ssc-data/config/computenode[12345678]_domain0.oes
df: (/production) not a block device, directory or mounted resource /production is not a mountpoint. Exiting.
Please correct this before re-starting. osc-domcreate will not be able to function until this is corrected.
[ Mar 5 14:50:42 Method "start" exited with status 100. ]
[ Mar 5 16:04:30 Leaving maintenance because disable requested. ] [ Mar 5 16:04:30 Disabled. ]

 

Changes

 Application of the JAN 2016 QFSDP

Cause

 Bug 22886768 - JAN 2016 QFSDP install_smu installing osc-domcreate on 1.x systems

The variations in the SuperCluster identifications caused install_smu to incorrectly identify the version of the system.

 

Solution

Please note that this Problem Solution applies to ONLY v 1.x systems.  Do not follow the procedures in this note for version 2.x systems.  The solution applies to all logical domains with the problem condition.

 

How to verify your system install version:

If you do not have ssc/identification service nor oes/id service and your SuperCluster is a T4-4 or early T5-8 SPARC SuperCluster then you can consider yourself 1.0 version and the solution applies

svcprop -p configuration/build ssc/identification
ssc-1.1.6

svcprop -p configuration/build oes/id
ssc-2.1.7

 

Resolution:

If you do not have ssc/identification service nor oes/id service and your SuperCluster is a T4-4 or early T5-8 SPARC SuperCluster then you can consider yourself 1.0 version and the solution applies

pkg uninstall osc-domcreate

 

 

 

References

<BUG:2288676> - XDELTA LIBRARIES FOR SOLARIS NOT BUILD CORRECTLY, HENCE CI/CO ERRORS

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback