Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2139916.1
Update Date:2017-08-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  2139916.1 :   T10000 - Head Brush Errors - FSCs: 5C1B, 5C1C, 5C3A, 5C3B, 5C5A, 5C7A, 5C8B  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions and later
Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
StorageTek T10000C Tape Drive - Version All Versions and later
StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 Head brush errors including these FSCs:  5C1B, 5C1C, 5C3A, 5C3B, 5C5A, 5C7A, 5C8B

Cause

 Errors associated with the head brush mechanical assembly.

Solution

Head brush errors including these FSC's: 5C1B, 5C1C, 5C3A, 5C3B, 5C5A, 5C7A, 5C8B are an indication of a mechanical problem internal to the drive.

The drive needs to be replaced if it is taking any of these errors. 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback