Asset ID: |
1-72-2138070.1 |
Update Date: | 2016-05-20 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2138070.1
:
I Have Alarm MPS UNAVAILABLE On EPAP Cards In The Eagle
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-12693502551>
Applies to:
Oracle Communications EAGLE (Software) - Version EAGLE 46.0 and later
Information in this document applies to any platform.
Symptoms
Both EPAPs show unavailable on Eagle.
Cause
Prov processes not running on EPAP A
* run: FAILURE:: MINOR::5000000000000002 -- Server Application Process Error
* run: FAILURE:: Only 0 instance(s) of provRMTP running. 4 instance(s) required!
run: Checking provRcvr...
* run: FAILURE:: MINOR::5000000000000002 -- Server Application Process Error
* run: FAILURE:: Only 0 instance(s) of provRcvr running. 4 instance(s) required!
run: Checking exinit...
Solution
Restarted software and issue resolved
Attachments
This solution has no attachment