Solution Type Problem Resolution Sure Solution 2136328.1 : SL150 - 9110 ROBOT_FRONT_VISION_FAILURE Accompanying 9080 MAG_OPEN_OR_UNLATCHED Messages
In this Document
Created from <SR 3-12436503341> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSudden appearance of 9080 messages in different modules. After replacing the Base Module to fix this issue there were also sensor issues in Module 7 that Field Engineer found smashed. The 9080 problem still occurred in other modules but always began with Led front Vision (9110) messages.
CauseDefective robot. SolutionRemoved and replaced the Robotic Module and solved the problem.
References<NOTE:1473453.1> - SL150 - How To Remove/Replace an Expansion Module Chassis FRU in the StorageTek SL150 Modular Tape Library [VCAP]<NOTE:1472418.1> - SL150 - How To Remove/Replace a Base Module Chassis FRU In the StorageTek SL150 Modular Tape Library [VCAP] <NOTE:1588654.1> - SL150 - 9080 Magazine Open or Unlatched <NOTE:2064290.1> - SL150 - Fails to Audit Mail Slot <NOTE:1952297.1> - SL150 – How to Update the Tape Drive Firmware via WEB BUI Attachments This solution has no attachment |
||||||||||||||||||
|