Asset ID: |
1-72-2136065.1 |
Update Date: | 2017-02-23 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2136065.1
:
Creating CSPC Group Gives Error
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-12531864201>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 45.0 and later
Tekelec
Symptoms
Entering SPC in the command ent-cspc, is aborted:
Expected Behavior: Customer expects that Point codes should be added.
Impact: No traffic impact. This is a new configuration being implemented by customer.
Cause
Although the Spare point code (s-xxxxx) and full point code (yyyyy) belong to ITU-N, they will have different NI values (Network Indicator)
For ITU National Binary Value: 0010
For ITU National Spare Binary Value: 0011
Hence system considers them to be from different network types. So unable to add them in a single CSPC.
Solution
1. Turn ON ANSI/ITU conversion feature
2. Re enter CSPC with point codes from different networks.
Attachments
This solution has no attachment