Solution Type Problem Resolution Sure Solution 2129304.1 : T10000B/C/D - FSC 4031 and 3016 Error Aborts The VSM Job.
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000D Tape Drive - Version All Versions and laterStorageTek T10000C Tape Drive - Version All Versions and later Sun StorageTek T10000B Tape Drive - Version All Versions and later Sun StorageTek T10000 Tape Drive - Version All Versions and later Information in this document applies to any platform. Symptoms4031 and 3016 error and the VSM job aborts. CauseDefective RFID transceiver writing corrupted data into the RFID chip in the media. SolutionT10000B/C/D - FSC 4031 along with 3016 FSC on the same mount. This may relate back to a bad RFID transceiver in a drive. Check to see what drive the affected tape was in prior to the 4031 and 3016 error. You need to check the mount history and find the first occurrence of 4031 and 3016 on the tape. Reference SR 3-12352830511. Attachments This solution has no attachment |
||||||||||||||||
|