Solution Type  Problem Resolution Sure

Solution  2129304.1 :   T10000B/C/D - FSC 4031 and 3016 Error Aborts The VSM Job.  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-12352830511>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
StorageTek T10000C Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Sun StorageTek T10000 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 4031 and 3016 error and the VSM job aborts.

Cause

 Defective RFID transceiver writing corrupted data into the RFID chip in the media.

Solution

T10000B/C/D - FSC 4031 along with 3016 FSC on the same mount. This may relate back to a bad RFID transceiver in a drive. Check to see what drive the affected tape was in prior to the 4031 and 3016 error. You need to check the mount history and find the first occurrence of 4031 and 3016 on the tape. Reference SR 3-12352830511.