Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2129186.1
Update Date:2017-11-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  2129186.1 :   xDR Builders Installation on the Mediation Sub-System Fails Because of the Wallet  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-12542492361>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.2.0 and later
Information in this document applies to any platform.

Symptoms

xDR builder installation on the IXP sub-system is failing with the error "unable to create connection to Oracle", in the Protocol Upgrade application when installing a new mediation sub-system.

Error

Changes

 

Cause

The step is needed just to create the datawarehouse (DWS) credentials in the wallet and sync to the mediation servers present in the sub-system.
 
The wallet procedure script is reporting the following error:

ERROR: Credential not correct for wallet. Exiting ?

Solution

Execute the procedure described in from the maintenance guide chapter Modify Database Password (chapter 7.16 in E60679 Revision 2).

If password is not known open a SR.
default passwords

https://cgbu-doccenter.us.oracle.com:16201/cs/groups/public/documents/technicalreference/z18y/nf8y/~edisp/cgbu_eng_24_2229.doc

References

<BUG:23122903> - MODIFYPASSWORD.SH DOES NOT REPORT ANY ERROR WHEN WALLET PASSWORD IS WRONG
<BUG:23121533> - WALLET CONFIGURATION IS MANDATORY
<BUG:23121723> - WALLET USE A DEFAULT PASSWORD

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback