![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2128217.1 : SL150 - Incorrect Fault Code 9091 Shown for a Track Error On the Robot
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSL150 - Incorrect Fault Code 9091 Shown for a Track Error On the Robot. This will cause the SL150 to go inoperative due to the following error messages: 2009-05-18T05:11:17.534, 0.0.0.0.0, 000, sensor-manager, , error, 0000, 8035, "getCheckProductIDSN: Base KLM module location reading 6, expecting 1." These are as a result of a track error on the robot. CauseThere is a bug in the SL150 code where a track error gets mapped to a 9091 fault code which will call out the incorrect part to replace. The 9091 fault code calls out the Base Chassis CRU to be replaced but in this specific scenario it is actually the robot that had an obstruction or is bad. define LIBMD_BASE_KLM_MODULE_MISMATCH_FAULT_CODE 9091 //_supported_ As reported in the Health File in the Service Bundle: 0045 - MOD_MB_BASE_MODULE_LOCATION_INCORRECT - Fault Code:9091 Probable Failed Components Actions to Take SolutionIf the 9091 is received and the above entries are found in the error log at the time of the 9091 then you should troubleshoot the Robot CRU and not the Base Chassis CRU. This was fixed in 2.60 code. In 2.60 and higher code the 9091 will state that you need to look for an obstruction that is causing the Z range to fail. Upgrade firmware to 2.60 or above. Attachments This solution has no attachment |
||||||||||||||||
|