Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2128217.1
Update Date:2017-07-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2128217.1 :   SL150 - Incorrect Fault Code 9091 Shown for a Track Error On the Robot  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: The log entries are Oracle Internal only

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SL150 - Incorrect Fault Code 9091 Shown for a Track Error On the Robot.

This will cause the SL150 to go inoperative due to the following error messages:

2009-05-18T05:11:17.534, 0.0.0.0.0, 000, sensor-manager, , error, 0000, 8035, "getCheckProductIDSN: Base KLM module location reading 6, expecting 1."
2009-05-18T05:11:17.539, 0.0.0.0.0, 000, sensor-manager, , error, 0000, 8035, "SensorMgr - setting library InOp due to Product ID issues!"

These are as a result of a track error on the robot.

Cause

There is a bug in the SL150 code where a track error gets mapped to a 9091 fault code which will call out the incorrect part to replace.

The 9091 fault code calls out the Base Chassis CRU to be replaced but in this specific scenario it is actually the robot that had an obstruction or is bad.

define LIBMD_BASE_KLM_MODULE_MISMATCH_FAULT_CODE 9091 //_supported_
faultCode=9091
faultString="MOD_MB_BASE_MODULE_LOCATION_INCORRECT"
helpString="Check for obstruction affecting robot vertical range. Replace base module chassis or have it's midplane replaced."
cru1="Chassis"
cru1Priority=1

As reported in the Health File in the Service Bundle:

0045 - MOD_MB_BASE_MODULE_LOCATION_INCORRECT - Fault Code:9091

Probable Failed Components
1. Module 1 Chassis

Actions to Take
Replace base module chassis or have it's midplane replaced.

Solution

If the 9091 is received and the above entries are found in the error log at the time of the 9091 then you should troubleshoot the Robot CRU and not the Base Chassis CRU.

This was fixed in 2.60 code.  In 2.60 and higher code the 9091 will state that you need to look for an obstruction that is causing the Z range to fail.

Upgrade firmware to 2.60 or above.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.