Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2128084.1
Update Date:2017-02-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  2128084.1 :   Card 1113 Error Reading Inactive Partition Table 13  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12523826691>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Tekelec

Symptoms

There is problem with executing the following command:

COPY-DISK:DLOC=1113:FORCE=YES:FORMAT=YES

 Here is output from terminal, Spare MASP never rebooted. System is in simplex mode.
 

stpclli 16-04-14 03:42:42 EST EAGLE5 46.2.0-67.10.0
  Card 1113 Module dmshc_utl.c Line 1100 DMS Error
  Error reading Active Partition table 3 on standby TDM (A);
  
  Requesting application id: H'0099;
  DMS0002: table not found on disk.
  
;
  stpclli 16-04-14 03:42:50 EST EAGLE5 46.2.0-67.10.0
  Card 1113 Module dmshc_utl.c Line 1100 DMS Error
  Error reading Active Partition table 3 on standby TDM (A);
  
  Requesting application id: H'0076;
  DMS0002: table not found on disk.
  
;
  stpclli 16-04-14 03:42:50 EST EAGLE5 46.2.0-67.10.0
  6075.1080 CARD 1113 INFO disk measurement status unreadable
  Report Date:16-04-14 Time:03:42:50
;
  stpclli 16-04-14 03:42:50 EST EAGLE5 46.2.0-67.10.0
  Card 1113 Module port_oam.c Line 226 Class 01b3 Severity 1
  00 00 ..
  Report Date:16-04-14 Time:03:42:50
;
  stpclli 16-04-14 03:42:50 EST EAGLE5 46.2.0-67.10.0
  Card 1113 Module dmshc_utl.c Line 1100 DMS Error
  Error reading Active Partition table 3 on standby TDM (A);
  
  Requesting application id: H'0076;
  DMS0002: table not found on disk.
  
;
  stpclli 16-04-14 03:42:51 EST EAGLE5 46.2.0-67.10.0
  Card 1113 Module dmshc_utl.c Line 1100 DMS Error
  Error reading Active Partition table 2 on standby TDM (A);
  
  Requesting application id: H'001e;
  DMS0002: table not found on disk.
  
;
  stpclli 16-04-14 03:42:51 EST EAGLE5 46.2.0-67.10.0
  6080.0052 CARD 1115 OAMHC TSC sync feature is available
;
  stpclli 16-04-14 03:42:51 EST EAGLE5 46.2.0-67.10.0
* 6085.0034 * CARD 1113 OAMHC Card database is inconsistent
;
  stpclli 16-04-14 03:42:52


Expected Behavior: Copy disk should be successful and both TDM databases should be Synced.
Impact: MASP System goes into Simplex Mode.

Cause

The issue is caused by a faulty Hardware.
 
EVIDENCE OF CAUSE
---------------
A faulty TDM hard drive can cause these alarms which prohibit system to reach certain tables.

SUPPORT OF CONCLUSION
---------------
Similar issue was previously observed, which was resolved by replacing the TDM.

REFERENCES
---------------
2-9408137 - Oracle Communications EAGLE (Software) EAGLE 44.x - Error reading inactive partition table2 on active TDM
 

Solution

1. Remove the faulty card
2. Insert the spare card
3. Wait for card to connect to the IMT
4. Run the command for copy disk again
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback