![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2127808.1 : VSM6: SLS6684I ECAM ERROR CC=5 RC=113
In this Document
Created from <SR 3-12154241061> Applies to:StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsCC5 RC113 RTD DDDDDD ON VTSS XXXXXXXX RETURNED ECAM ERROR CC=5 RC=113 Explanation: No real tape cartridge was mounted. When the command was initially User Response: Eject the MVC cartridge and examine it for any visual defect that may CauseVSM6 RTD that is already online reacts to a VARY ONLINE command from another host when the other host is being started. VSM6 should have ignored the ECAM request to vary online the RTD when the RTD is already online. Instead VSM6 did a cleanup of the RTD resulting in a READY of the drive. This was followed by a dismount of the MVC, ECAM CC=5 RC=113, and re-mount the MVC. After that operations continue running as normal.
SolutionThe VSM6 fix is in microcode 6.3.0.05.000. VSM6 will no longer issue a VARY ONLINE when an RTD or vRTD is already online. References<BUG:22710572> - ECAM ERROR CC=5 RC=113Attachments This solution has no attachment |
||||||||||||||||||
|