Asset ID: |
1-72-2127492.1 |
Update Date: | 2016-04-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2127492.1
:
Eagle DSMs Not Updating
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-12532841091>
Applies to:
Oracle Communications EAGLE (Software) - Version EPAP 16.0 and later
Information in this document applies to any platform.
Symptoms
DB Level not increasing on Eagle DSM cards.
Cause
Undetermined
Solution
1) Logging into the GUI of the Active EPAP (which was EPAP B)
2) Activating "Forced Standby" to make EPAP B "Standby". This caused EPAP A to become active and start updating the cards.
3) Removing the "Forced Standby" from EPAP B, once the cards caught up.
Attachments
This solution has no attachment