Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2127492.1
Update Date:2016-04-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  2127492.1 :   Eagle DSMs Not Updating  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12532841091>

Applies to:

Oracle Communications EAGLE (Software) - Version EPAP 16.0 and later
Information in this document applies to any platform.

Symptoms

DB Level not increasing on Eagle DSM cards.

Cause

Undetermined

Solution


1) Logging into the GUI of the Active EPAP (which was EPAP B)
2) Activating "Forced Standby" to make EPAP B "Standby". This caused EPAP A to become active and start updating the cards.
3) Removing the "Forced Standby" from EPAP B, once the cards caught up.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.