Asset ID: |
1-72-2126785.1 |
Update Date: | 2017-09-11 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2126785.1
:
SL150 - Drive Is Malfunctioning, "BridgeDriver(1)::fillTaskMgmtEvent() - LUN Reset"
Related Items |
- StorageTek SL150 Modular Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
In this Document
Created from <SR 3-12520704709>
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.
SL150 is running 2.50 code.
Symptoms
Ultrium 5-SCSI bridge drive malfunctioning.
2016-04-12T04:10:41.415 warn 0.0.0.0.0 1103 "BridgeDriver(1)::fillTaskMgmtEvent() - lun reset"
2016-04-12T04:18:12.401 warn 0.0.0.0.0 1103 "BridgeDriver(1)::fillTaskMgmtEvent() - terminate task"
2016-04-12T04:18:22.401, 0.0.0.0.0, 1005, scsi-bridge, , error, 1207, 1103, "BridgeDriver(1)::allocCommand()-bridgePacket allocation failed"
Warning Log:
2016-04-12T03:24:25.411, 0.0.0.0.0, 1005, scsi-bridge, , warn, 1207, 1103, "BridgeDriver(1)::fillTaskMgmtEvent() - terminate task"
2016-04-12T03:24:35.413, 0.0.0.0.0, 1005, scsi-bridge, , warn, 1207, 1103, "BridgeDriver(1)::fillTaskMgmtEvent() - terminate task"
2016-04-12T03:24:35.425, 0.0.0.0.0, 1005, scsi-bridge, , warn, 1207, 1103, "BridgeDriver(1)::fillTaskMgmtEvent() - lun reset"
2016-04-12T03:32:06.410, 0.0.0.0.0, 1005, scsi-bridge, , warn, 1207, 1103, "BridgeDriver(1)::fillTaskMgmtEvent() - terminate task"
2016-04-12T03:32:16.408, 0.0.0.0.0, 1005, scsi-bridge, , warn, 1207, 1103, "BridgeDriver(1)::fillTaskMgmtEvent() - terminate task"
2016-04-12T03:32:16.420, 0.0.0.0.0, 1005, scsi-bridge, , warn, 1207, 1103, "BridgeDriver(1)::fillTaskMgmtEvent() - lun reset"
Cause
Bug numbers are: 22862635 and 22743405
Solution
There are 2 different bugs that have been address with the 3.0 release.
The work around for code less then 3.0 would be:
See if the customer is using SSO for Netbackup If so then they need to configure the use of "Persistent Reservations" in SSO to prevent too many hosts trying to use the bridge drive and library at the same time.
Attachments
This solution has no attachment