Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2126585.1
Update Date:2017-03-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2126585.1 :   EAGLE MOID Related Alarm Generated In PIC From Eagle  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-12395151914>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 44.0.2 to EAGLE 46.2 [Release EAGLE 44.0 to EAGLE 46.0]
Oracle Communications Performance Intelligence Center (PIC) Software - Version 4.1 and later
Tekelec

Symptoms

Following alarms are being sent from Eagle on PIC:

MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2002480414.1113.0 from host aa7-imf-1b
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2002480414.1113.0 from host aa7-imf-1c
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2002480414.1115.0 from host aa7-imf-1b
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2002480414.1115.0 from host aa7-imf-1c
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2002480414.1115.0 from host aa7-imf-1d
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2007068135.1113.0 from host bb7-imf-1a
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2096357360.1113.0 from host cc7-imf-1a
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2096357360.1115.0 from host cc7-imf-1a
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2097310703.1113.0 from host cc7-imf-1c
MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2097310703.1115.0 from host cc7-imf-1c

Changes

 

Cause

Following alarms are reported on EAGLE during this issue:

6135.0084 ** DLK 1115,A OAMHC IP Connection Unavailable ****16-03-23 04:01:41****
6381.0084 ** DLK 1113,A OAMHC IP Connection Unavailable ****16-03-23 06:00:31****

The problem on PIC side is that above mentioned Eagle alarms are forwarded to the NSP but the NSP does not interpret them (MO_OID not found). These alarms should not be reaching PIC.

The following justifies how the issue is related to this specific customer: Alarm on PIC coincides with the OAM IP Connection Unavailable Alarm for cards 1113 and 1115.

Two examples below:

On PIC: 23/03/2016 04:01:37 MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2096357360.1115.0 from host aa7-imf-1a
On Eagle: 6135.0084 ** DLK 1115,A OAMHC IP Connection Unavailable ****16-03-23 04:01:41****

On PIC: 23/03/2016 06:00:30 MO_OID NOT Found .1.3.6.1.4.1.4404.21.0.2096357360.1113.0 from host aa7-imf-1a
On Eagle: 6381.0084 ** DLK 1113,A OAMHC IP Connection Unavailable ****16-03-23 06:00:31**

This is explained in the bug 19116482 - [239218]IP Connection Unavailable/Available alarm on OAMHC forwarded to IMF 

Solution

To implement the solution, please upgrade Eagle to version 46.2.0-65.53.1 or above.

References

<BUG:19116482> - [239218]IP CONNECTION UNAVAILABLE/AVAILABLE ALARM ON OAMHC FORWARDED TO IMF BUT

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.