Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2126021.1
Update Date:2017-07-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2126021.1 :   SL3000 - Rotational CAPs Only Open Halfway, 3955, "Error From Device Code: 752 - CAP Move Failed  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12505530230>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

CAP = Cartridge Access Port

Symptoms

Rotational CAPs on a SL3000 will only open halfway.. Getting error 752.. Cap move failed.

2016-04-10T00:26:10.249, 1.1.-2.2.0, root, default, internal, 0, error, 3955, "Error from device Code: 752 - Cap move failed - ok to retry", Data=<response sequence="2767" final="true"><command>moveToPosition</command><result><resultStatus><resultSeverity>error</resultSeverity><operationalState>752</operationalState><resultCode>7502</resultCode><resultText>Motor Stalled</resultText></resultStatus></result></response>

2016-04-10T03:26:57.714, 1.1.5.2.0, root, default, internal, 0, error, 3955, "Error from device Code: 752 - Cap move failed - ok to retry", Data=<response sequence="752" final="true"><command>moveToPosition</command><result><resultStatus><resultSeverity>error</resultSeverity><operationalState>752</operationalState><resultCode>7502</resultCode><resultText>Motor Stalled</resultText></resultStatus></result></response>

 

Cause

The CAP cartridge array was not seated properly after the last time it was removed. When putting the array back into to the CAP assembly care must be taken to seat the array properly by gently pushing down after inserting the array.

Solution

 Reseated the CAP cartridge array and CAP was able to open all the way.