Power Consumption Alarm UAM 0520
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-12287342808>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 44.0.4 to EAGLE 46.2 [Release EAGLE 44.0 to EAGLE 46.0]
Tekelec
Symptoms
UAM 0520 and UAM 0521 observed for Frame Power Usage:
0176.0521 ** FRAME CF00 Frame power usage reached LVL2
0177.0520 *C FRAME EF00 Frame power usage reached LVL3
Impact:
The alarm shows that frames are drawing power that is above the power thresholds set (rtrv-frm-pwr)
Cause
E5-E1T1-B cards configured as LIME1 returns invalid BIP data after init-card or inh-card/alw-card.
rtrv-bip reports "Board ID Prom retrieve failure: prom data undefined"
The following justifies how the issue is related to this specific customer:
Customer has E5-E1T1B Cards set as LIME1.
This is explained in the following bug:
Bug 22128374 - LIME1 on E5-E1T1-B card return invalid BIP data after a warm reboot
Solution
To implement the solution, please execute the following steps:
1. Check the cards that have BIP alarm. Run:
Rept-stat-trbl:display=timestamp
2. Physically reseat the card
3. Perform rept-stat-card:mode=full and check if the BIP alarm is now clear
4. Perform step 2 and 3 for all LIME1 cards that have been identified with BIP alarm
5. Check power consumption. It should be under the threshold limits: rtrv-stp:display=power
References
<BUG:22128374> - SR: LIME1 ON E5-E1T1-B CARD RETURN INVALID BIP DATA AFTER A WARM REBOOT