Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2124797.1
Update Date:2017-03-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2124797.1 :   Apply Change on IXP Subsystem is Failing With Error: "Stream Can't Write; Duplicate Key in Table 'Stream'"  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-12473246611>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 4.1 and later
Information in this document applies to any platform.

Symptoms

CCM Users are not able to apply changes on a given IXP subsystem and getting the following error message:

"Failed to apply changes because of the following errors : Stream Can't write; duplicate key in table 'Stream'"

Changes

 

Cause

During the manual creation of a new DFP, CCM user created 2 output streams having exactly the same name. As the stream name is a primary key on the "Stream" table of the IXP IDB database, the IXP doesn't accept the new configuration and consequently returns the above described error during the "Apply Changes".

When checking the configuration of the new DFP under "CCM -> Distribution", the newly created DFP is having 2 output streams having exactly the same name.

Solution

Go to "CCM -> Distribution" menu and identify the DFP having duplicate stream name.

Once identified, edit the DFP configuration and change the streams' names in a way that duplication is eliminated.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.