In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-12261770611>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.5 and later
Oracle Database Appliance Software - Version 12.1.2.6 and later
Information in this document applies to any platform.
When the assistant is executed for the ODA system it-self the validation step to check the information is skip.
You can go through the Validation screen only when you execute it from a laptop for example

Symptoms

ODA installation has failed with the Error in Step10 (ValidateEnv):

Screenshot

There are the following errors in the assistant log located in /tmp:

Mar 07, 2016 3:36:02 AM oracle.onecommand.data.ValidationErrors addError
INFO: Added validation error:Invalid Domain Name
Mar 07, 2016 3:36:44 AM oracle.onecommand.data.ValidationErrors addError
INFO: Added validation error:Invalid DNS Server IP1

Cause

A fake DNS Server and domain needs to be configured in the assistant in order to move to the next screen.

Solution

On the second screen of the ODA select a custom installation instead of the Typical.

Configuration type

This will add the step "Generic Network" in the assistant where you can enable the checkbox "No DNS Server available"

Generic Network

References

<BUG:22959418> - ODA INSTALLATION MUST BE UPDATED TO TAKE IN ACCOUNT THE RELEASE SUPPORTING X5-2
<NOTE:888888.1> - Oracle Database Appliance - 12.1.2 and 2.X Supported ODA Versions & Known Issues
<NOTE:2048836.1> - ODA (Oracle Database Appliance): Deployment without DNS fails at Step 16