![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2121537.1 : How to Install an Oracle Database Appliance (ODA) Without Configuring a DNS
In this Document
Created from <SR 3-12261770611> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.5 and laterOracle Database Appliance Software - Version 12.1.2.6 and later Information in this document applies to any platform. When the assistant is executed for the ODA system it-self the validation step to check the information is skip. You can go through the Validation screen only when you execute it from a laptop for example SymptomsODA installation has failed with the Error in Step10 (ValidateEnv): There are the following errors in the assistant log located in /tmp: Mar 07, 2016 3:36:02 AM oracle.onecommand.data.ValidationErrors addError
INFO: Added validation error:Invalid Domain Name Mar 07, 2016 3:36:44 AM oracle.onecommand.data.ValidationErrors addError INFO: Added validation error:Invalid DNS Server IP1 CauseA fake DNS Server and domain needs to be configured in the assistant in order to move to the next screen. SolutionOn the second screen of the ODA select a custom installation instead of the Typical. This will add the step "Generic Network" in the assistant where you can enable the checkbox "No DNS Server available" References<BUG:22959418> - ODA INSTALLATION MUST BE UPDATED TO TAKE IN ACCOUNT THE RELEASE SUPPORTING X5-2<NOTE:888888.1> - Oracle Database Appliance - 12.1.2 and 2.X Supported ODA Versions & Known Issues <NOTE:2048836.1> - ODA (Oracle Database Appliance): Deployment without DNS fails at Step 16 Attachments This solution has no attachment |
||||||||||||||||||
|