Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2120592.1
Update Date:2016-06-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  2120592.1 :   Performance Intelligence Center, in NSP Cannot Delete the Linkset to Synchronize the IMF  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-12366662916>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.3 and later
Information in this document applies to any platform.

Symptoms

It is not possible to delete a link or linkset.

Cause

In Enterprise manager one session was locking nsp internal table.

Following log can be find in NSP application.log:

System error: Please contact your System Administrator
2016-03-16 16:36:36,042 - ERROR - NSP - Centralized Configuration - tekelec - BUSINESS - Exception caught inside SS7LinkServiceModel.validateDeleteLink()::null - com.steleus.nsp.config.system.exception.ValidationException
at weblogic.rmi.internal.ServerRequest.sendReceive(ServerRequest.java:205)
at weblogic.rmi.cluster.ClusterableRemoteRef.invoke(ClusterableRemoteRef.java:345)

Solution

Find the blocking session in NSP Oracle Enterprise Manager or look at 1924794.1.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.