Solution Type Problem Resolution Sure Solution 2119619.1 : Performance Intelligence Center (PIC) Way Field Is Not Properly Assigned on Xdr for IMF Traffic From STC Card
In this Document
Created from <SR 3-12366736291> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 7.1 and laterInformation in this document applies to any platform. SymptomsIn xDR, The WAY field is not the one expected when traffic is coming from STC card. It should be incoming if DPC=Eagle PC and outgoing if OPC=Eagle PC. CauseWhen STC copy is used, way is provided by Eagle. Coding Indication in Eagle PDU:
IMF sends this information to IXP with every PDU. There is a LongParam in IMF to manage how this could be interpreted. [cfguser@IMF-1A ~]$ iqt -p LongParam | grep -i dir
Yes InvertMsuDirForMfp 1 Before sending to ICP/IXP, invert MSU direction reported by Eagle. Default is to invert By default value is inverted. SolutionChange the InvertMsuDirForMfp 0 on all IMFs to swap way incoming/outgoing. References<NOTE:1995432.1> - How to Decode Eagle Monitoring Protocol (EMP) Messages in Wireshark ?Attachments This solution has no attachment |
||||||||||||||||||
|