Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2117864.1
Update Date:2017-06-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  2117864.1 :   SL150 - Fails Boot with "K_IDcard failed. code 8." Boot Up Error  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 This documents assists with resolving an issue with the SL150 when it fails to boot with the error "K_IDcard failed. code 8."

Changes

 None

Cause

If you receive this error during the boot up sequence of the SL150 then the USB stick on the KLM card in the Base Module is either bad or it is corrupt.

Solution

 A Base Chassis CRU will need to be dispatched out to the customer to fix this issue.