Solution Type  Problem Resolution Sure

Solution  2117296.1 :   LSMS Full Shanpshot - Snapshot /dev/vgroot/dbbackup  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12243278011>

Applies to:

Oracle Communications EAGLE (Software) - Version LSMS 13.1 and later
Information in this document applies to any platform.

Symptoms

LSMS - Snapshot /dev/vgroot/dbbackup is grater than 90 percent critical showing on LSMS.

Cause

snapshot partition present due to failed backup attempts

Solution

I killed 2 old backup processes and removed the volume with " /usr/TKLC/lsms/tools/post-backup/db/clear_db_snapshot.pl".