Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2115679.1
Update Date:2016-03-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2115679.1 :   Exalogic: ZFS-7320 ILOM Network Settings Lost on X2-2 and X3-2 Racks After PSU Upgrade  


Related Items
  • Oracle Exalogic Elastic Cloud Software
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
  • Exalogic Elastic Cloud X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exalogic/OVCA>Oracle Exalogic>MW: Exalogic Core
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 to X2 [Release X2]
Exalogic Elastic Cloud X3-2 Hardware - Version X3 to X3 [Release X3]
Oracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 and later
Oracle Solaris on x86-64 (64-bit)
Linux x86-64
Oracle Virtual Server x86-64

Symptoms

Following the upgrade of the ZFS-7320 ILOM on Exalogic X2-2 and X3-2 racks, it is observed that the network settings for the ZFS ILOM are lost. The following settings are observed upon logging in to the ZFS ILOM and viewing the network settings:

-> show /SP/network
/SP/network
Targets:
interconnect
ipv6
test
Properties:
commitpending = (Cannot show property)
dhcp_clientid = none
dhcp_server_ip = (none)
ipaddress = (none)
ipdiscovery = (none)
ipgateway = (none)
ipnetmask = (none)
macaddress = 00:10:E0:0E:39:4B
managementport = NET0
outofbandmacaddress = 00:10:E0:0E:39:4A
pendingipaddress = (none)
pendingipdiscovery = (none)
pendingipgateway = (none)
pendingipnetmask = (none)
pendingmanagementport = NET0
sidebandmacaddress = 00:10:E0:0E:39:4B
state = ipv6-only
Commands:
cd
set
show

However, the ZFS ILOM continues to be accessible over its configured IP address. This is a display-only issue. Exalogic racks X4-2 and X5-2 containing the ZS3-ES Storage Appliance are not affected.

Cause

This issue is tracked through the following ILOM bug:

BUG 22766793 - Updating Exalogic X2-2 from 2.0.x.x.x to 2.0.6.2.x loses ILOM Network settings

The bug causes the network info for eth0 (aka NETMGMT) to be displayed rather than the "current configured management port" (which is SIDEBAND on Exalogic).

Solution

This is a display-only issue, and may be ignored, since the ZFS ILOM continues to be accessible over its configured IP address. A fix is currently in progress.

References

<NOTE:2093675.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Solaris - Physical) for January 2016
<NOTE:2093674.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Linux - Virtual) for January 2016
<NOTE:2093676.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Linux - Physical) for January 2016

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback