Symptoms
Failed RTDB backup alarm
Cause
Backup failed because ELAP software was already stopped when autobackup attempted to start and was not able to determine status of RTDB/ELAP while software stopped.
Solution
Clear alarm with "alarmMgr --clear TKSMPSMI9" and removed alarm with 'echo "" > /usr/TKLC/epap/bin/pdbRtdbAlarm'