![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2115618.1 : SL3000 - FSC(1104) Drive Destination Full
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsFSC(1104): Drive destination full Cause2016-03-10T19:20:40.403, 1.1.1.1.2, root, hli2, move,15109960, error, 1104, "Drive destination full - checkStates", hliLsm=0 drive=1,1,1,1,2 SolutionCheck the SPLAT log for further error messages. If it is only one short event and the drive worked after the event, no more action is needed. Should there be multiple error messages, investigate Log Snapshot further to better understand the problem. 2016-03-11T03:11:54.609, 1.1.1.1.2, root, default, internal, 0, trace, 3952, "From device", Data=stateChangeNoticedrive busyRewindingfalsefalsefalse 2016-03-11T03:12:03.941, 1.1.1.1.2, root, hli2, move,15114400, trace, 3952, "From device", Data=rewindUnloadinfo0000<!|CDATA|drive 1,1,1,1,2: rewindUnload Successful||>000 2016-03-11T03:12:04.124, 1.1.1.1.2, root, hli2, move,15114400, trace, 3952, "From device", Data=requestToFetchinfo0000<!|CDATA|drive 1,1,1,1,2: requestToFetch Successful (state = cartridgePresent, enableLibraryMode = 0)||>000 2016-03-11T03:12:06.909, 1.1.1.1.2, root, hli2, move,15114400, trace, 3953, "To device", Data=fetchComplete9 Attachments This solution has no attachment |
||||||||||||||||
|