Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2115268.1
Update Date:2017-06-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2115268.1 :   SL500 - All Drives Are Going Down in Networker. Getting Read I/O Errors on All Drives After Tapes are Being Mounted  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Cause
Solution
 Applies to:


Created from <SR 3-12285752336>

Applies to:

Sun StorageTek SL500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
SL500 Version: 1501 (7.22.00)

2016-03-02 15:37:33 Volumes with failures on multiple drives found in logs:
CD0098L3 - Drives: 0,2,1,9 , 0,4,4,9
Last message seen: 2016-03-02 09:38:56
CD2308L3 - Drives: 0,2,1,9 , 0,4,3,9
Last message seen: 2016-03-02 09:38:55
CD2344L3 - Drives: 0,2,1,9 , 0,4,2,9
Last message seen: 2016-03-02 09:40:36
CD2959L3 - Drives: 0,2,1,9 , 0,4,4,9
Last message seen: 2016-03-02 09:41:13
CD3477L3 - Drives: 0,2,1,9 , 0,4,2,9
Last message seen: 2016-03-02 09:41:50
CD4260L3 - Drives: 0,2,2,9 , 0,3,1,9
Last message seen: 2016-03-02 15:12:35
CD4903L3 - Drives: 0,2,1,9 , 0,4,3,9
Last message seen: 2016-03-02 09:41:12

2016-03-02 15:37:33 Volumes found in logs (count)
CD0098L3 (4)
CD1030L3 (3)
CD1542L3 (3)
CD2308L3 (4)
CD2344L3 (6)
CD2959L3 (4)
CD3477L3 (4)
CD4260L3 (5)
CD4903L3 (2)
CD5844L3 (3)
CD7301L3 (3)
CD7653L3 (5)

Symptoms

All drives are going down in Networker. Getting read I/O errors on all drives after tapes are being mounted.

Cause

 Media issues.

Solution

It would appear there is some media issues going on. The above tapes should be looked at to determine whether they are damaged or have pulled leaders.
Run some diagnostics to the library to verify functionality.
Do load/unload tests to the drives to verify they are working properly.
Look for any loose or damaged bezels and fix accordingly.

Applies to:

Sun StorageTek SL500 Modular Library System
1-914CU


Attachments
This solution has no attachment