![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2115268.1 : SL500 - All Drives Are Going Down in Networker. Getting Read I/O Errors on All Drives After Tapes are Being Mounted
In this Document
Created from <SR 3-12285752336> Applies to:Sun StorageTek SL500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. SL500 Version: 1501 (7.22.00) 2016-03-02 15:37:33 Volumes with failures on multiple drives found in logs: CD0098L3 - Drives: 0,2,1,9 , 0,4,4,9 Last message seen: 2016-03-02 09:38:56 CD2308L3 - Drives: 0,2,1,9 , 0,4,3,9 Last message seen: 2016-03-02 09:38:55 CD2344L3 - Drives: 0,2,1,9 , 0,4,2,9 Last message seen: 2016-03-02 09:40:36 CD2959L3 - Drives: 0,2,1,9 , 0,4,4,9 Last message seen: 2016-03-02 09:41:13 CD3477L3 - Drives: 0,2,1,9 , 0,4,2,9 Last message seen: 2016-03-02 09:41:50 CD4260L3 - Drives: 0,2,2,9 , 0,3,1,9 Last message seen: 2016-03-02 15:12:35 CD4903L3 - Drives: 0,2,1,9 , 0,4,3,9 Last message seen: 2016-03-02 09:41:12 2016-03-02 15:37:33 Volumes found in logs (count) CD0098L3 (4) CD1030L3 (3) CD1542L3 (3) CD2308L3 (4) CD2344L3 (6) CD2959L3 (4) CD3477L3 (4) CD4260L3 (5) CD4903L3 (2) CD5844L3 (3) CD7301L3 (3) CD7653L3 (5) SymptomsAll drives are going down in Networker. Getting read I/O errors on all drives after tapes are being mounted. CauseMedia issues. SolutionIt would appear there is some media issues going on. The above tapes should be looked at to determine whether they are damaged or have pulled leaders. Applies to:Sun StorageTek SL500 Modular Library System Attachments This solution has no attachment |
||||||||||||||||||
|