Asset ID: |
1-72-2114953.1 |
Update Date: | 2017-05-15 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2114953.1
:
Passwords Lost After Executing "halt" Command on Oracle AP 4600
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
|
In this Document
Created from <SR 3-12139252801>
Applies to:
Acme Packet 4600 - Version E-Cz7.3.0 to E-Cz7.3.0 [Release E-Cz7.0]
Acme Packet 4600
Symptoms
After running the halt command on an AP 4600 running ECZ730m1, the SBC Administrator may find that device is no longer accepting previous passwords.
This behavior may present as the following:
Starting display manager...
Initializing /opt/ Cleaner
Starting tLogCleaner task
Bringing up shell...
password secure mode is enabled
Admin Security is disabled
Starting SSH...
SSH_Cli_init: allocated memory for 5 connections
number of telnet sessions initialized:5
#############################################################################
Please load/place only 64 bit images on here, i.e. nnECZ730m1.64.bz
Please also, do NOT load any admin security license on this device!!
#############################################################################
Password:
% Login failed
#############################################################################
Please load/place only 64 bit images on here, i.e. nnECZ730m1.64.bz
Please also, do NOT load any admin security license on this device!!
#############################################################################
Password:
*ALERT*
*****************************************************************
user password has not been set. Please set password now.
*****************************************************************
** Only alphabetic (upper or lower case), numeric and punctuation
** characters are allowed in the password.
** Password must be 8 - 64 characters,
** and have 3 of the 4 following character classes :
** - lower case alpha
** - upper case alpha
** - numerals
** - punctuation
*****************************************************************
Enter New Password:
Confirm New Password:
Password is acceptable.
SD-4600-131-1> en
Password:
*ALERT*
*****************************************************************
admin password has not been set. Please set password now.
*****************************************************************
** Only alphabetic (upper or lower case), numeric and punctuation
** characters are allowed in the password.
** Password must be 8 - 64 characters,
** and have 3 of the 4 following character classes :
** - lower case alpha
** - upper case alpha
** - numerals
** - punctuation
*****************************************************************
Enter New Password:
Confirm New Password:
Password is acceptable.
Cause
This is a known defect, tracked within Bug 22677425.
Solution
The solution to 22677425 was formally delivered within product updates SCZ730m1, and ECZ730m2.
References
<BUG:22697425> - PASSWORD LOST AFTER EXECUTING HALT COMMAND
Attachments
This solution has no attachment