![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2114516.1 : Exalogic X2-2 Compute Nodes ILOM Network Settings Lost After PSU Upgrade
In this Document
Applies to:Oracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 and laterOracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 to X2 [Release X2] Linux x86-64 Oracle Solaris on x86-64 (64-bit) Oracle Virtual Server x86-64 SymptomsFollowing the upgrade of compute node ILOM on Exalogic X2-2 racks, it is observed that the network settings for the ILOM are lost. The following settings are observed upon logging in to the ILOM and viewing the network settings: -> show /SP/network
/SP/network Targets: interconnect ipv6 test Properties: commitpending = (Cannot show property) dhcp_clientid = none dhcp_server_ip = (none) ipaddress = (none) ipdiscovery = (none) ipgateway = (none) ipnetmask = (none) macaddress = 00:10:E0:0E:39:4B managementport = NET0 outofbandmacaddress = 00:10:E0:0E:39:4A pendingipaddress = (none) pendingipdiscovery = (none) pendingipgateway = (none) pendingipnetmask = (none) pendingmanagementport = NET0 sidebandmacaddress = 00:10:E0:0E:39:4B state = ipv6-only Commands: cd set show However, the ILOM continues to be accessible over its configured IP address. This is a display-only issue. Racks other than X2-2 are not affected. CauseThis issue is tracked through the following bug: BUG 22766793 - Updating Exalogic X2-2 from 2.0.x.x.x to 2.0.6.2.x loses ILOM Network settings
The bug causes the network info for eth0 (aka NETMGMT) to be displayed rather than the "current configured management port" (which is SIDEBAND on Exalogic). SolutionThis is a display-only issue, and may be ignored, since the ILOM continues to be accessible over its configured IP address. A fix is currently in progress. References<NOTE:1995223.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.1 (Linux - Physical) for April 2015<NOTE:2093675.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Solaris - Physical) for January 2016 <NOTE:2093674.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Linux - Virtual) for January 2016 <NOTE:2093676.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Linux - Physical) for January 2016 <NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues <NOTE:1995236.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.1 (Linux - Virtual) for April 2015 <NOTE:2027107.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.2 (Solaris - Physical) for July 2015 <NOTE:2027098.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.2 (Linux - Virtual) for July 2015 <NOTE:2027108.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.2 (Linux - Physical) for July 2015 <NOTE:2057614.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.3 (Solaris - Physical) for October 2015 <NOTE:2057607.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.3 (Linux - Virtual) for October 2015 <NOTE:2057632.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.3 (Linux - Physical) for October 2015 <NOTE:1995235.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.1 (Solaris - Physical) for April 2015 Attachments This solution has no attachment |
||||||||||||||||||
|