Solution Type Problem Resolution Sure Solution 2114423.1 : T10000B - FSC5904. File Reel Amplifier Was Saturated For Too Long
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000B Tape Drive - Version All Versions and laterInformation in this document applies to any platform. Type: T100000B Rev: 1.50.203 SymptomsFile reel amplifier was saturated for too long. FSC: 5904 REEL_CTL_FSC_FILE_AMP_SATURATED. Cause5904 FSC can be caused by one or more rollers binding in the tape path. It can also be caused by stiction problems with certain tapes. SolutionMultiple 5904 errors being seen on different tapes and wraps.
Applies to:Sun StorageTek T10000B Tape Drive Attachments This solution has no attachment |
||||||||||||||||||
|