Symptoms
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-12310152507>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Type: T100000B Rev: 1.50.203

Symptoms

File reel amplifier was saturated for too long.

FSC: 5904 REEL_CTL_FSC_FILE_AMP_SATURATED.

Cause

5904 FSC can be caused by one or more rollers binding in the tape path. It can also be caused by stiction problems with certain tapes.

Solution

Multiple 5904 errors being seen on different tapes and wraps.
Recommend the drive be replaced.


 

Applies to:

Sun StorageTek T10000B Tape Drive