Solution Type Problem Resolution Sure Solution 2112780.1 : SL24 - Autoloader Error - Blinking Ready and Attention LED
In this Document
Created from <SR 3-12270488091> Applies to:Sun StorageTek SL24 Tape Autoloader - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Symptoms Storagetek SL24 Autoloader error - not getting ready mode. Cause Issue with media SolutionPower off the SL24 Autoloader for few minutes and power on the SL24 Autoloader and run the Wellness test. Clean the drive using known good cleaning media. Replace the drive if the issue still persists.
References<NOTE:1449276.2> - Information Center: Sun StorageTek SL24 Tape AutoloaderAttachments This solution has no attachment |
||||||||||||||||||
|