Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2112413.1
Update Date:2016-08-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2112413.1 :   Diameter Signaling Router (DSR) - Sends Corrupted Answer Message Of Length=20 Bytes Causing Connection To Go Down [dsr#22311{Invalid Diameter message received}]  


Related Items
  • BNS Platform Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-12027344561>

Applies to:

BNS Platform Hardware - Version DSR 5.0 to DSR 5.0 [Release DSR 5.0]
Information in this document applies to any platform.

Symptoms

2 tier DSR (Software Version: 5.0.1_50.26.0) receives correctly formed Answer message but while routing this Answer message DSR sends only 20 byte of header causing connection to go down.
It is also noticed that 2 tier DSR (Software Version: 5.0.1_50.26.0) on receiving such malformed message routes it to peer node.

Following error messages are seen on DSR sending the malformed Answer message indicating Invalid Diameter Message Received and Semantic Error. 

err logs:

01/18/2016 03:36:46 dsr#22311{Invalid Diameter message received}
.. GN_INFO/INF Diameter Connection Name=<>, Diameter Connection ID=<>, Peer Node FQDN=<>, Semantic Error ID=<>, Msg Octets= <>
^^ [31777:ConnectionHandler.<>]

If the peer to which this Answer message is sent is a DSR (other than 5.0.1_50.26.0) then it reports following error in dsr logs and err logs indicating that connection is unavailable due to malformed message and Length=20bytes

01/18/2016 04:01:31 dsr#22302{Connection Unavailable: Received malformed message}
.. GN_INFO/INF Diameter Connection Name=<>, Diameter Connection ID=<>, Peer Node FQDN=<>, Length=20, Msg Octets= <>
^^ [30180:SctpConnectionHandler.<>]

 

Cause

This issue has been addressed under Bug# 22342941 and Bug# 22354413.

Solution

Bug# 22342941 and Bug# 22354413 are being worked by Engineering.

Upgrade to DSR 6.0 or later to fix this issue.

References

<BUG:22342941> - ANSWER TRUNCATION DURING ENCODING IN DSR 5.0
<BUG:22354413> - DSR SENDING ONLY DIAMETER HEADER IN ANSWER MESSAGE