Solution Type  Problem Resolution Sure

Solution  2111656.1 :   SL8500 - Microcode Update in a Complex Fails  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

L8500 Microcode Update in a Complex Fails.

Unable to Obtain the Required Lock.

Cause

Attempting to load code from multiple SLConsole sessions will result in the failure "Unable to Obtain the Required Lock" failures in the SLConsole.

Solution

When loading and activating microcode in an SL8500 complex, make sure only one SLConsole is attempting to load/activate code if the complex option is chosen.

Attempting to reactivate the prior version could get a lock error when trying to unpack the earlier version. Libraries running 6.0X and higher code support simultaneous Load/Unpack/Activate of microcode. Make sure your PC has the minimum required SLConsole version that supports the code you are loading. The recommended SLConsole is FRS-6.60 for all code versions.