![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2111536.1 : Oracle ZFS Storage Appliance: SMU 1.2 - Unable to take backup
In this Document
Created from <SR 3-12160179981> Applies to:Oracle ZFS Storage ZS3-2 - Version All Versions and laterOracle ZFS Storage ZS3-4 - Version All Versions and later Oracle ZFS Storage ZS3-BA - Version All Versions and later Oracle ZFS Storage ZS4-4 - Version All Versions and later Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsSnap Management Utility is not able to take backup. When the backup launched, SMU reports the following error: Task Failed. Application Oracle Database nashead does not use Sun ZFS storage.
ChangesNo changes, new installation.
CauseFibre Channel client connectivity is not supported with SMU.
SolutionWith SMU, the only supported configurations are NFS or ASM over iSCSI LUNs: https://docs.oracle.com/cd/E39520_01/pdf/E39313.pdf
Alternatively, the customer can use Oracle Secure Backup with FC.
References<BUG:16789648> - FC SUPPORT WITH SMU FAILS ON CLUSTERED ZFSSA HEADAttachments This solution has no attachment |
||||||||||||||||||||
|