Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2110691.1
Update Date:2017-07-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2110691.1 :   SL150 - Library Not Scanning Expansion CAP  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-12051577954>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Expanded mail slot was not scanned, but regular 4 mail slot were scanned. Manual library audit was required to scan tapes in expanded mail slots.

No Fault Code available from log bundle.

 

Changes

 No changes made by customer.

Cause

 Faulty right side magazine sensor on Base module.

Solution

Replace Base module.

Refer to:

SL150 - How To Remove/Replace a Base Module Chassis CRU In the StorageTek SL150 Modular Tape Library [VCAP] (Doc ID 1472418.1)

   

 

 

References

<NOTE:1474172.1> - SL150 - How to Find Firmware Update Patches and Upgrade the StorageTek SL150 Modular Tape Library With Those Firmware Patches
<NOTE:1952297.1> - SL150 – How to Update the Tape Drive Firmware via WEB BUI

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.