![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2110374.1 : Oracle ZFS Storage Appliance: DE2-24x JBOD Serial Number seen on the front right-hand flange may not match the value seen in the BUI/CLI
In this Document
Created from <SR 3-11079892751> Applies to:Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-BA - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsThe DE2-24x JBOD serial number on the front right-hand flange does not match with the serial number shown in the ZFSSA Browser User Interface or Command Line Interface. CauseThe rack installation of the DE2-24x JBOD's may require the front right-hand flange to be removed for tightening the screw underneath them on the side rails. This flange with serial number is sometime swapped with a consecutive or the other chassis during the initial installation. Such situations may subsequently cause confusion while replacing hardware or identifying JBODs in the BUI or CLI.
SolutionTo overcome the confusion, the BUI/CLI serial number and the physically available serial number has to be validated. The following steps are given in order to validate the serial number.
Using BUI : Click the locator LED on Hardware > Maintenance > Disk Shelves > Name
Alternatively in CLI : Enable the chassis activity indicator LED using: zfs:maintenance chassis-xxx> set locate=true
locate = true (uncommitted) zfs:maintenance chassis-xxx> commit zfs:maintenance chassis-xxx> show Properties: name = xxxx faulted = xxxx manufacturer = Oracle model = Oracle Storage DE2-24C part = xxxx serial = xxxxxx ........ locate = true <<<<<
Once the LED is set to ON, physically validate the serial number and swap the flange only if it does NOT match the serial number shown in the BUI / CLI.
Do you still have questions? You can use My Oracle Support Communities. Communities put you in touch with industry professionals like yourself. They are monitored by Oracle support engineers, so you can expect reliable and correct answers. Ask questions and see what others are asking about in the Disk Storage ZFS Storage Appliance Community.
Attachments This solution has no attachment |
||||||||||||||||
|