![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2108985.1 : T10000C - RTDs Giving MEDIA WARRANTY EXPIRED Message
T10000 RTD with early Media Warranty Life reported In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000C Tape Drive - Version All Versions to Not Applicable [Release All Releases to N/A]Information in this document applies to any platform. SymptomsLot of MVCs were marked as “warranty expired” in the MVCRPT. Reviewing the VOLPRT’s. CauseALP Criteria The T10000B/C/D tape drives will also post expiration for tapes if certain ALP related thresholds are exceeded. This is done to prevent wearing out of 1 section of tape (for example if there was an active ALP that is referenced frequently).This expiration criteria is calculated/checked whether or not the account uses the ALP feature and regardless whether or not the tape is actually written in ALP format. The media vendor does not recognize T10000 media as being expired due to any ALP expiration criteria and this criteria is not factored into the Media Warranty Life (MWL) number presented by the drive. SolutionUpgrade T10000C RTDs to firmware RA362112 or higher References<BUG:22552481> - GKVI IS REQUESTING SPECIAL BUILD FOR MEDIA WARRANTY EXPIRED MESSAGE<NOTE:2029570.1> - T10000 - Media Expiration Criteria Attachments This solution has no attachment |
||||||||||||||||||
|