Solution Type  Problem Resolution Sure

Solution  2108390.1 :   HBA Shows Max NPIV Ports: 7  


Related Items
  • SPARC T7-2
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-12202550411>

Applies to:

SPARC T7-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Customer reports: HBA shows Max NPIV Ports: 7

HBA Port WWN: 2100000e1e2b9610
Port Mode: Initiator
Port ID: a1d00
OS Device Name: /dev/cfg/c8
Manufacturer: QLogic Corp.
Model: 7023303
Firmware Version: 7.05.01
FCode/BIOS Version: BIOS: 3.24; fcode: 4.06; EFI: 5.50;
Serial Number: 463916T+1528243832
Driver Name: qlc
Driver Version: 150505-5.03b
Type: N-port
State: online
Supported Speeds: 4Gb 8Gb 16Gb
Current Speed: 8Gb
Node WWN: 2000000e1e2b9610
Link Error Statistics:
Link Failure Count: 0
Loss of Sync Count: 0
Loss of Signal Count: 0
Primitive Seq Protocol Error Count: 0
Invalid Tx Word Count: 0
Invalid CRC Count: 0
Max NPIV Ports: 7 <----------------

 

The default Max NPIV Ports: should be 254

HBA Port WWN: xxxxxxxx
Port Mode: Initiator
Port ID: 0
OS Device Name: /dev/cfg/c19
Manufacturer: QLogic Corp.
Model: 7023303
Firmware Version: 6.6.3
FCode/BIOS Version: BIOS: 3.19; fcode: 4.02; EFI: 5.36;
Serial Number: 463916T+1341156205
Driver Name: qlc
Driver Version: 20130621-4.02b
Type: unknown
State: offline
Supported Speeds: 4Gb 8Gb 16Gb
Current Speed: not established
Node WWN: yyyyyyyy
Max NPIV Ports: 254 <---------------
NPIV port list:

 

Changes

 Qlogic FC driver should allow maximum 254 NPIV ports when SR-IOV is not enabled

Cause

You are most likely running into: Bug 21963495 - Qlogic FC driver should allow maximum 254 NPIV ports when SR-IOV is not enabled

Currently the maximum NPIV ports is 7 even when SR-IOV is not enabled in the new firmware/driver.
This is very restrictive and a serious regression with prior (non-SRIOV)
implementation, which allows 254 for the maximum NPIV ports.

 


example taken recently from a customer's configuration HBA Port

 

WWN: 2100000e1e101401
Port Mode: Initiator
Port ID: 1
OS Device Name: /dev/cfg/c4
Manufacturer: QLogic Corp.
Model: 7023303
Firmware Version: 7.05.01
FCode/BIOS Version: BIOS: 3.19; fcode: 4.02; EFI: 5.36;
Serial Number: 0402A00-1232045676
Driver Name: qlc
Driver Version: 150505-5.03b
Type: point-to-point
State: online
Supported Speeds: 4Gb 8Gb 16Gb
Current Speed: 16Gb
Node WWN: 2000000e1e101401
Max NPIV Ports: 254 <---------------------------
NPIV port list:

 

 

HBA Port WWN: 2100000e1e255f90
Port Mode: Initiator
Port ID: 1
OS Device Name: /dev/cfg/c12
Manufacturer: QLogic Corp.
Model: 7023303
Firmware Version: 7.05.01
FCode/BIOS Version: BIOS: 3.24; fcode: 4.06; EFI: 5.50;
Serial Number: 463916T+1506231683
Driver Name: qlc
Driver Version: 150505-5.03b
Type: point-to-point
State: online
Supported Speeds: 4Gb 8Gb 16Gb
Current Speed: 16Gb
Node WWN: 2000000e1e255f90
Max NPIV Ports: 7
NPIV port list:
 

 

Solution

 Waiting for Fix of Bug 21963495

Qlogic FC driver should allow maximum 254 NPIV ports when SR-IOV is not enabled

References

<BUG:21963495> - QLOGIC FC DRIVER SHOULD ALLOW MAXIMUM 254 NPIV PORTS WHEN SR-IOV IS NOT ENABLED

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.