Solution Type  Problem Resolution Sure

Solution  2107775.1 :   Infinicheck Reports Alerts/warning And Also "Subnet Masks Differ" On Exadata Rack  


Related Items
  • Exadata X5-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12198912961>

Applies to:

Exadata X5-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

On : All Versions version

ACTUAL BEHAVIOR
---------------
Infinicheck reports alerts/warning and also "Subnet masks differ" on Exadata rack

Infinicheck reports alerts/warning along with message "subnet masks differ"


Cause

The tests error out with

[SUBNET MASKS DIFFER].....2 entries found


due to not having cleaned out after previous runs done with infinicheck
 
When only one or a few nodes but not all are cleaned out with the '-z' option to infinicheck, subsequent runs of inifnicheck will error out.
 

Solution

By running:

./infinicheck -z -g </opt/oracle.SupportTools/onecommand/dbs_group>

and then the normal inifnicheck which failed, the subnet mask error is not seen.
 