Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2105288.1
Update Date:2016-08-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  2105288.1 :   Upgrade From DSR 5.0.1 To 7.0.1: Guest NO A Is Unable To Have Xmi Interface Up  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-12073663901>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.

Symptoms

 After upgrade of the TVOE, NOAM GUI would not launch. Reason for NOAM not launching is that the xmi ip address is not up.

Cause

During the firmware upgrade they would of had to reboot. If the ifcfg-xmi was changed before the reboot they would of had the same issue. Since there was no issue, that we are aware of, after the firmware upgrade. I have to suspect the "rcstool co ifcfg-xmi" command was executed after the firmware and before the TVOE upgrade.

Solution

Run the command "rcstool ci ifcfg-xmi" to allow the owner


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.