2103411.1
:
SGSN and GGSN IP addresses are inverted in Gb over IP session
Related Items |
- Oracle Communications Performance Intelligence Center (PIC) Software
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
|
In this Document
Created from <SR 3-12006327771>
Applies to:
Oracle Communications Performance Intelligence Center (PIC) Software - Version 4.1 and later
Information in this document applies to any platform.
Symptoms
SGSN and GGSN IP are not the good ones in the Gb over IP session
Cause
The way management is not configured in the PMF IP dataflow used to feed the build DFP.
The way management feature is used to provide information about the way of the frames to the IXP and builders for protocols based on IP layer.
Solution
Configure the BSCs IP subnet in the way management in the dataflow used to monitor Gb over IP traffic.