![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2103094.1 : The Hardware And Firmware Does Not Match With The Profile reported for DiskControllerBatteryBackupUnitVersion
Created from <SR 3-12007716091> Applies to:Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsWhen executing "/opt/oracle.SupportTools/CheckHWnFWProfile" output displays: : [WARNING] The hardware and firmware does not match with the profile. See details below
<Check_Result Server_Model="SUN_FIRE_X4270_M3"> <Check_Result_for_DiskController> <DiskController> <DiskControllerBatteryBackupUnitVersion> <<<<==== Checking Battery Backup. <Required VALUE="iBBU08"/> <Found VALUE=""/> <<<<==== Found Value reports NULL value </DiskControllerBatteryBackupUnitVersion> </DiskController> </Check_Result_for_DiskController> </Check_Result>
ChangesExachk was run CauseThe root cause of this being reported is Hardware issue with the Battery Backup Unit. SolutionThe resolution to to open an SR for replacement of the Battery Backup Unit Hardware (BBU). Attachments This solution has no attachment |
||||||||||||
|