Asset ID: |
1-72-2102294.1 |
Update Date: | 2017-05-18 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2102294.1
:
T10000D - Field problems Addressed In 4.10.106 microcode
Related Items |
- StorageTek T10000D Tape Drive
- Sun StorageTek T10000 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Applies to:
Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Identify field problems fixed in 4.10.106 code.
Cause
Identify field problems fixed in 4.10.106 code.
Solution
Code changes in 4.10.106 Microcode for T10000D Tape Drives.
* 37F6 Perm read error when reading a legacy written cartridge on a D drive.
* Fix for TSM (6.3.4.5) error when DPKM encryption is enabled.
* New Oracle corporate compliance rules for SNMP support.
* Fix for a customer reporting 329D SNO's on multiple drives.
* Fix for a customer account that is seeing 31F4 perm errors on RTD's.
* Fix for a customer that reported Tape Alert Flags were not resetting in the drive upon the next mount of a tape.
* RRAO/GRAO performance changes that were released in special code RC409107.
* Fix for a customer there reported seeing 601F SNO's.
* 367B FSC - changes the reporting of tape End Of Life from being reported on every mount to being reported only once.
* Service Request to configure SNMP target addresses using VOP without requiring the IPL of a T10KD drive to make the configuration changes.
* 2BFF - fix for a customer reporting that T10KD drives were getting 2BFF SNO's with 4.09.107 code where drives were set into 3592 emulation. This replaces Special Build RD409107.
* 5535 - servo code change to reduce or eliminate 5535 errors on load.
Attachments