![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2102018.1 : M10-1 Cannot Locate HDD with cfgadm -x locator=on c0::dsk/c0t5000039668222832d0
In this Document
Created from <SR 3-11746604631> Applies to:Fujitsu M10-1 - Version All Versions to All Versions [Release All Releases]Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases] Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. Symptoms
The "cfgadm -x locator=on" command on specific internal disk returns with message "cfgadm: Configuration operation not supported". Example: root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t5000039668222832d0
cfgadm: Configuration operation not supported root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t5000039668221DC2d0 cfgadm: Configuration operation not supported root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t500003966822226Ad0 cfgadm: Configuration operation not supported root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t50000396681B9C92d0 cfgadm: Configuration operation not supported
CauseThe cfgadm -x option use the cfgadm SCSI plugin: "-x locator[={on|off}]". This allows a user to turn on or turn off the locator indication, regardless of the underlying implementation.
SolutionInstall SunOS 5.10: cfgadm patch 150542 (current -01): SunOS 5.10: cfgadm patch References<BUG:20612961> - FORWARD PORT 20578158 TO S12 - CFGADM PLUGIN FOR FUJITSU M10 NEEDS TO SUPPORT LAttachments This solution has no attachment |
||||||||||||||||||
|