Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2102018.1
Update Date:2017-10-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2102018.1 :   M10-1 Cannot Locate HDD with cfgadm -x locator=on c0::dsk/c0t5000039668222832d0  


Related Items
  • Fujitsu M10-4
  •  
  • Fujitsu M10-4S
  •  
  • Fujitsu M10-1
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-11746604631>

Applies to:

Fujitsu M10-1 - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 

The "cfgadm -x locator=on"  command on specific internal disk returns with message "cfgadm: Configuration operation not supported".

Example:

root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t5000039668222832d0
cfgadm: Configuration operation not supported
root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t5000039668221DC2d0
cfgadm: Configuration operation not supported
root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t500003966822226Ad0
cfgadm: Configuration operation not supported
root@xs01-ctl # cfgadm -x locator=on c0::dsk/c0t50000396681B9C92d0
cfgadm: Configuration operation not supported

 

Cause

The cfgadm -x option use the cfgadm SCSI plugin: "-x locator[={on|off}]". This allows a user to turn on or turn off the locator indication, regardless of the underlying implementation.
Reason the -x locator option did not work was because of a missing SCSI plugins for the cfgadm implementation.

 

Solution

Install SunOS 5.10: cfgadm patch 150542  (current -01): SunOS 5.10: cfgadm patch
 

References

<BUG:20612961> - FORWARD PORT 20578158 TO S12 - CFGADM PLUGIN FOR FUJITSU M10 NEEDS TO SUPPORT L

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback