Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2101671.1
Update Date:2017-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2101671.1 :   SL8500 - Service Required Light On, Incomplete Init of H-Bots During First Power-Up after New Build  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SL8500 - Service Required Light On, Incomplete Init of H-Bots During First Power-Up after New Build.

Cause

 Incorrect cable connections.

Solution

Check the J406 and J407 cables that run along the right floor of the machine for swapped connectors. There are from 2 to 6 pair of these connectors (depending on number of Expansion Modules) beginning at the RIM interconnect. Also be sure to check the J404/J405 connections at the left corner of the RIM/DEM.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.