Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2100783.1
Update Date:2017-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2100783.1 :   T10000D - Incorrect SFPs Used As Spares  


Related Items
  • StorageTek T10000D Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 Incorrect SFP used as a spare. Cannot communicate with the host.

Cause

 Incorrect SFP modules used.

Solution

Some incorrect SFPs were shipped as spares for P/N 7063109.
GOOD:Finisar FTL F8529P3BCV (Avago AFBR 57F5PZ?)
BAD:Avago AFBR 703SDZ

A purge is being done in the depots for this part.

In order to obtain a good SFP simply order P/N 7063109 again as the bad SFPs have been purged from the system.

No further action is required, just order a replacement part to install in the drive.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback