Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2100122.1
Update Date:2018-01-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2100122.1 :   UAM 0451 "Database Reload is Required"  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-11892415981>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Symptoms

The customer is having from time to time the UAM 451 RTDB Reload required

Cause

There are bouncing at the Ethernet layer on both ports of the SCCP cards
 
  ****15-12-20 00:45:43****
  2988.0540 ENET 1207,B Ethernet Interface Up
  ****15-12-20 00:45:43****
  2987.0540 ENET 1207,A Ethernet Interface Up
  ****15-12-20 00:38:10****
  2474.0539 ** ENET 1305,B Ethernet Interface Down
  ****15-12-20 00:38:09****
  2472.0539 ** ENET 1305,A Ethernet Interface Down
  ****15-12-20 00:36:27****
  2351.0539 ** ENET 1207,B Ethernet Interface Down
  ****15-12-20 00:36:27****
  2350.0539 ** ENET 1207,A Ethernet Interface Down
  ****15-12-20 00:34:16****
  2205.0540 ENET 3107,B Ethernet Interface Up
  ****15-12-20 00:34:16****
  2204.0540 ENET 3107,A Ethernet Interface Up
  ****15-12-20 00:34:15****
  2199.0540 ENET 1107,B Ethernet Interface Up
  ****15-12-20 00:34:15****
  2198.0540 ENET 1107,A Ethernet Interface Up
  ****15-12-20 00:26:53****
  1693.0539 ** ENET 3107,B Ethernet Interface Down
  ****15-12-20 00:26:53****
  1692.0539 ** ENET 3107,A Ethernet Interface Down
  ****15-12-20 00:26:19****
  1649.0539 ** ENET 1107,B Ethernet Interface Down
  ****15-12-20 00:26:18****
  1648.0539 ** ENET 1107,A Ethernet Interface Down
  ****15-12-20 00:19:08****
  1169.0540 ENET 3317,B Ethernet Interface Up
  ****15-12-20 00:19:08****
  1168.0540 ENET 3317,A Ethernet Interface Up
  ****15-12-20 00:19:07****
  1163.0540 ENET 3215,B Ethernet Interface Up
  ****15-12-20 00:19:07****
  1162.0540 ENET 3215,A Ethernet Interface Up
 

Solution

This Ethernet issue has to be solved.
I am doubting you are having 2 faulty switches, so it must be something in-between, please check the cabling and whatever which could impact the proper connections at the Ethernet layer with both switches.
The power feed ? Anything creating some noise in the Ethernet connections ? Grounding issue ?
Maybe could you try to power off and power on the switches and see if it helps ?
 