Solution Type  Problem Resolution Sure

Solution  2098518.1 :   ES2-64 PSU Error  


Related Items
  • Oracle Ethernet Switch ES2-64
  •  
  • Oracle Ethernet Switch ES2-72
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-11979433701>

Applies to:

Oracle Ethernet Switch ES2-64 - Version All Versions to All Versions [Release All Releases]
Oracle Ethernet Switch ES2-72 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 When Connecting to the ILOM using the browser, the "Open Problems" shows the following:

   1 Tue Dec 29 18:00:02 2015 Power PS1 (Power Supply 1)
   Description: Sensors indicate that a power supply is not operating correctly. (Probability:100, UUID:a80b3fe8-
   5da9-4800-f055-99078ab94f12, Resource:/SYS/PS1, Part Number:7065505-01, Serial Number:C95495, Reference
   Document:http://support.oracle.com/msg/ETHSWITCH-8000-2D)


   2 Wed Jan 20 15:55:12 2016 Power PS0 (Power Supply 0)
   Description: Sensors indicate that a power supply is not operating correctly. (Probability:100, UUID:6105dec2-
   8811-c43a-992b-f564ad904150, Resource:/SYS/PS0, Part Number:7065505-01, Serial Number:C95501, Reference
   Document:http://support.oracle.com/msg/ETHSWITCH-8000-2D)

 

Cause

 This is a known issue with firmware version 2.0.0.5 when the system is not yet started.

Solution

 This is fixed in release 2.0.0.7.

For release 2.0.0.5 and below, use the following work around.

Start the system from the SP ILOM

 -> start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS

References

<BUG:22372814> - ILOM DETECTED PSU FAULT
<NOTE:1155200.1> - PSH Procedural Article for ILOM-Based Diagnosis
<NOTE:1448069.1> - How to run an ILOM Snapshot on a Sun/Oracle X86 System
<NOTE:2076783.1> - ETHSWITCH-8000-2D - Power supply internal failure
<NOTE:1310998.1> - ILOM "Warning: The system appears to be in manufacturing test mode"

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback