![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2098518.1 : ES2-64 PSU Error
In this Document
Created from <SR 3-11979433701> Applies to:Oracle Ethernet Switch ES2-64 - Version All Versions to All Versions [Release All Releases]Oracle Ethernet Switch ES2-72 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsWhen Connecting to the ILOM using the browser, the "Open Problems" shows the following: 1 Tue Dec 29 18:00:02 2015 Power PS1 (Power Supply 1)
CauseThis is a known issue with firmware version 2.0.0.5 when the system is not yet started. SolutionThis is fixed in release 2.0.0.7. For release 2.0.0.5 and below, use the following work around. Start the system from the SP ILOM -> start /SYS References<BUG:22372814> - ILOM DETECTED PSU FAULT<NOTE:1155200.1> - PSH Procedural Article for ILOM-Based Diagnosis <NOTE:1448069.1> - How to run an ILOM Snapshot on a Sun/Oracle X86 System <NOTE:2076783.1> - ETHSWITCH-8000-2D - Power supply internal failure <NOTE:1310998.1> - ILOM "Warning: The system appears to be in manufacturing test mode" Attachments This solution has no attachment |
||||||||||||||||||
|