Asset ID: 1-72-2096489.1
Update Date:2016-09-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2096489.1 :   Oracle ZFS Storage Appliance: Destroying an Old/Previous Software Package Reports Error  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-8292001457>

Applies to:

Sun ZFS Storage 7120 - Version All Versions and later
Sun ZFS Storage 7420 - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
Sun Storage 7110 Unified Storage System - Version All Versions and later
Sun Storage 7210 Unified Storage System - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

Destroying the old/previous software package from CLI does not work.

When destroying via the BUI, the status shows "deleting" but after some time the status again changes to "previous".

 

Unable to clean up old firmware package in ZFS and below error messages are reported:


    Error1 : "aksh: uncaught error exception (code EAKSH_NAS_NOENT) in script: cannot open 'system/ak-nas-2011.04.24.8.1_1-2.44.3.5/boot': filesystem does not exist"

    Error2 : "cannot destroy 'system/ak-nas-2011.04.24.1.0_1-1.8/install': filesystem has children use '-r' to destroy the following datasets:system/ak-nas-2011.04.24.1.0_1-1.8/install/svc

    "/usr/lib/ak/update/up_delete: line 76: destroy of system/ak-nas-2011.04.24.1.0_1-1.8/install failed:"

 

Cause

 Package is already deleted from Solaris, but not refreshed from AKD

 

Solution

Perform an AKD (Appliance Kit Daemon) restart that will allow deletion of the package from aksh.

Customer can perform a  "Maintenance System restart" to restart the management interface.

NOTE: The BUI/CLI will not be accessible until the AKD restart completes.

 

If issue is not fixed, you will need to engage Oracle Support, by opening a Service Request, so that Oracle Support Services can provide confirmation of this issue and then carry out the appropriate activities to resolve the issue.

 

For Oracle Support Engineer:  Restart AKD from the appliance shell

 