Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2096470.1
Update Date:2017-09-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2096470.1 :   SL3000 - Defective HBT Card Causes All drives and Drive Power Supplies To Be Missing in SLConsole  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-11903355841>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.




When you say 'customer use lowest config for power supply' do you mean N+1? If so you need to say N+1 so there is no confusion.

Sorry for confuse. Customer use 2N config ( PDU1+PDU2) but they install wrong EM(Electronics Module) power supply to 23 and 24 ,The 2N config should 23 and 26. for drive power supply ,they only install to 6 and 7.only got power form PDU1.

Symptoms

All power supply related drive (power supply locations 4/5/6/7/8/9/10/11) are missing in SLC but we can see the LED of these power supplies are green and fans are working. We can see all drive trays have power but drives have no power.

HBT active LED not lit and CLI command status is OK.

The ceiling LED light on.

All LED of PUN card are normal and correct.

 

Changes

One drive tray power supply failure and all drive status changed to offline ,after reboot library ,the drive tray power supplies and drives are missing in SLConsole.

Cause

 The customer uses the lowest configuration for power supplies. Once one power supply fails only one power supply is left in the library and this caused HBT card failure. The HBT didn't send signal to drive tray that provides power to drive.

Solution

 1. Try to confirm if all location of drive power supplies missing in SLC (drive power supply are 4、5、6、7 related PDU1 and 8、9、10、11 related PDU2).

 2. If only the driver power supplies related to one PDU missing, the PUF card is most suspected.

 3. Check PUN card led status confirm PUN card is healthy.

 4. If PUN card also good. check HBT card led status ,if active led light on after library reboot.

 5. If HBT card active light off , even if status is OK check, with CLI command , replace HBT and reboot library.

CLI command example:

SL3000> hbt status *

requestId

requestId 14701

Attributes Fault Led off
Healthy true

Present true

Reset Board off

Select enable

Object Card hbta

Attributes Fault Led off
Healthy false

Present false

Reset Board off

Select disable

Object Card hbtb

Done

Failure Count 0

Success Count 2

COMPLETED